Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/viend961/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the jetpack domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/viend961/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the polylang domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/viend961/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the interface domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/viend961/public_html/wp-includes/functions.php on line 6131
Capto™ L antibody fragment purification resin – VIEN DONG TECHNICAL COMPANY LIMITED
Deprecated: Function WP_Dependencies->add_data() was called with an argument that is deprecated since version 6.9.0! IE conditional comments are ignored by all supported browsers. in /home/viend961/public_html/wp-includes/functions.php on line 6131

Capto™ L antibody fragment purification resin

Capto™ L antibody fragment purification resin

Description

Capto™ L resin is designed for antibody fragment purification, when the fragment contains the kappa light chain.

Capto™ L resin is available in the following prepacked formats: HiTrap™ Protein L prepacked columns, HiScreen™ Capto™ L prepacked columns, and PreDictor™ Capto™ L 96-well plates.

* Suitable for the capture of a wide range of antibody fragments such as Fabs, dAbs, and single-chain fragment variable (scFv) .
* High binding capacity, low ligand leakage, and selectivity for a broad range of antibody fragments reduces process time and amount of resin.
* Enables a platform approach to antibody fragment purification.
* Excellent productivity, process economy, and process design flexibility due to rigid matrix.
* Hydrophilic base matrix ensures low levels of non-specific binding and low levels of host cell-derived impurities in the elution pool.
* Fulfills industrial demands for security of supply, robust performance, and regulatory support.

Affinity resin for antibody fragment purification
Capto™ L combines a rigid, high-flow agarose matrix with the immunoglobulin-binding recombinant protein L ligand, which has a strong affinity to the variable region of antibody kappa light chains.

The high binding capacity and affinity to a broad range of antibody fragments makes this resin an excellent capture platform for antibody fragments containing kappa light chains. Common uses include domain antibody (dAb), scFv, and Fab purification.

Using this protein L resin
Capto™ L resin requires minimal optimization and produces high purity in one separation step, resulting in significant savings during process development. This resin is also advantageous in manufacturing, because high selectivity of affinity capture reduces the number of subsequent polishing steps.

Streamlined scale up
Scale-up with this resin is straightforward and is further aided by a range of prepacked process development tools, such as PreDictor™ plates, PreDictor™ RoboColumn™, and HiScreen™ prepacked columns.

Successful use in published research
Capto™ L is used in applications requiring the purification of antibody fragments through protein L affinity chromatography.

Compatible empty columns – research scale
Capto™ L resin is compatible with empty PD gravity flow, Tricorn™, XK, and HiScale™ columns.

Compatible empty columns – bioprocess scale
For process-scale applications, Cytiva recommends AxiChrom™ columns.

Convenient prepacked columns – research scale
Capto™ L resin is available in the following formats:

HiTrap™ Protein L prepacked columns: convenient for easy use with a syringe, peristaltic pump, or chromatography system
HiScreen™ Capto™ L prepacked columns, for method and process development
PreDictor™ Capto™ L 96-well plates, for high-throughput screening or process development

Convenient prepacked columns – bioprocess scale
Prepacked ReadyToProcess™ columns are available, eliminating the need for column packing and cleaning validation.

Order Cytiva – Capto™ L Spec Cytiva – MabSelect PrismA™ Spec Cytiva – Capto™ L

Specification

Specification

Ordering information

Ordering information